Difference between revisions of "MT174"
Jump to navigation
Jump to search
(Created page with "=== ISKRA MT174 === thumb|ISKRA MT174 ISKRA MT174 (230/400V, rated 85A) mostly used in Saxonia this seems to have some noticable semaphores wich can be...") |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | === ISKRA MT174 === | + | ===ISKRA MT174=== |
[[File:ISKRAMT174.png|thumb|ISKRA MT174]] | [[File:ISKRAMT174.png|thumb|ISKRA MT174]] | ||
ISKRA MT174 (230/400V, rated 85A) mostly used in Saxonia | ISKRA MT174 (230/400V, rated 85A) mostly used in Saxonia | ||
this seems to have some noticable semaphores wich can be visualy inspected: | this seems to have some noticable semaphores wich can be visualy inspected: | ||
− | + | KD = lid/cover open (there must be a switch somewhere) | |
− | KD = lid/cover open (there must be a switch somewhere) | + | BAT = internal battery low |
− | BAT = internal battery low | + | DÜ = transmission mode |
− | DÜ = transmission mode | + | FF = "Fatal" counter (?) |
− | FF = "Fatal" counter (?) | + | SET = counter in program mode |
− | SET = counter in program mode | ||
The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models. | The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models. | ||
− | The "Fatal counter" is a hex value 8bit flag register: | + | The "Fatal counter" is a hex value 8bit flag register: |
− | 0 = Firmware error | + | 0 = Firmware error |
− | 1 = Counter parameter checksum error | + | 1 = Counter parameter checksum error |
− | 2 = energy/maximum checksum error | + | 2 = energy/maximum checksum error |
− | 3 = not used | + | 3 = not used |
− | 4 = not used | + | 4 = not used |
− | 5 = not used | + | 5 = not used |
− | 6 = maintenance warning level (?) | + | 6 = maintenance warning level (?) |
− | 7 = not used | + | 7 = not used |
+ | [https://www.youtube.com/watch?v=tKAOW3Ykq9A EMP test] | ||
[https://www.youtube.com/watch?v=fOnKzUN7SzU Tampering / manipulation log video] | [https://www.youtube.com/watch?v=fOnKzUN7SzU Tampering / manipulation log video] | ||
+ | |||
+ | [https://www.youtube.com/watch?v=SEQTSzwD-t4 Explaining basic concepts] | ||
[[File:ISKRA LOG.png|thumb|FIFO logbook P.98.1 for 74 "possible misuse type events"]] | [[File:ISKRA LOG.png|thumb|FIFO logbook P.98.1 for 74 "possible misuse type events"]] | ||
− | [https:// | + | [https://www.avu-netz.de/downloads/messwesen/anleitung_mt174_1_kurzanleitung.pdf Manual (short)] |
[https://www.manualslib.de/manual/417563/Iskraemeco-Mt174.html?page=33#manual Manual] | [https://www.manualslib.de/manual/417563/Iskraemeco-Mt174.html?page=33#manual Manual] |
Latest revision as of 21:23, 8 March 2024
ISKRA MT174
ISKRA MT174 (230/400V, rated 85A) mostly used in Saxonia this seems to have some noticable semaphores wich can be visualy inspected:
KD = lid/cover open (there must be a switch somewhere) BAT = internal battery low DÜ = transmission mode FF = "Fatal" counter (?) SET = counter in program mode
The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models.
The "Fatal counter" is a hex value 8bit flag register:
0 = Firmware error 1 = Counter parameter checksum error 2 = energy/maximum checksum error 3 = not used 4 = not used 5 = not used 6 = maintenance warning level (?) 7 = not used