<blockquote> | <blockquote>The C9321SK-05 consists of a megapixel (1056 x 1056 elements) detector array, each of 50 micron size, to provide a total X-ray sensitive area of roughly 7,5 centimetres. | ||
The X-ray imager utilises a gadox scintillator deposited onto a fibre-optic plate, to provide an effective X-ray shield. This fibre-optic provides both improved image quality (lower X-ray shot noise) and it shields the sensitive CMOS electronics inside the panel, thus giving extended lifetime of 6 million Roentgen guaranteed at 150 kVp. | The X-ray imager utilises a gadox scintillator deposited onto a fibre-optic plate, to provide an effective X-ray shield. This fibre-optic provides both improved image quality (lower X-ray shot noise) and it shields the sensitive CMOS electronics inside the panel, thus giving extended lifetime of 6 million Roentgen guaranteed at 150 kVp. | ||
Compared to previous flat panel sensors, the C9321SK-05 also offers higher frame rates of 9 frames per second at full resolution and the device is capable of realtime imaging at 27 frames per second with 2 x 2 binning.<ref>https://www.dataweek.co.za/print.aspx?editorialtype=N&editorialid=26151</ref></blockquote> | Compared to previous flat panel sensors, the C9321SK-05 also offers higher frame rates of 9 frames per second at full resolution and the device is capable of realtime imaging at 27 frames per second with 2 x 2 binning.<ref>https://www.dataweek.co.za/print.aspx?editorialtype=N&editorialid=26151</ref></blockquote> | ||
=== Exterior Pictures === | |||
<gallery mode="packed" heights="300"> | |||
File:Hamamatsu C9321SK 6812207 Overview Picture.jpg | |||
File:Hamamatsu C9321SK 6812207 Model and Serial Number.jpg | |||
File:Hamamatsu C9321SK 6812207 Data Connector.jpg | |||
</gallery> | |||
=== Teardown Pictures === | === Teardown Pictures === | ||
<gallery mode="packed" heights="300"> | |||
File:Hamamatsu C9321SK 6812207 Lid Underside.jpeg | |||
File:Hamamatsu C9321SK 6812207 Lid removed.jpg | |||
File:Hamamatsu C9321SK 6812207 IMG 0935.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0938.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0937.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0944.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0945.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0949.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0948.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0947.jpeg | |||
File:Hamamatsu C9321SK 6812207 IMG 0946.jpeg | |||
</gallery> | |||
=== High Resolution PCB Pictures === | |||
<gallery mode="packed" heights="300"> | |||
File:Hamamatsu C9321SK 6812207 XM06D-Sensor Top.jpg | |||
File:Hamamatsu C9321SK 6812207 XM06D-Sensor Bottom.jpg | |||
File:Hamamatsu C9321SK 6812207 XM06D-ControlBoard Top.jpg | |||
File:Hamamatsu C9321SK 6812207 XM06D-ControlBoard Bottom.jpg | |||
</gallery> | |||
Latest revision as of 22:18, 22 August 2026
The C9321SK-05 consists of a megapixel (1056 x 1056 elements) detector array, each of 50 micron size, to provide a total X-ray sensitive area of roughly 7,5 centimetres.
The X-ray imager utilises a gadox scintillator deposited onto a fibre-optic plate, to provide an effective X-ray shield. This fibre-optic provides both improved image quality (lower X-ray shot noise) and it shields the sensitive CMOS electronics inside the panel, thus giving extended lifetime of 6 million Roentgen guaranteed at 150 kVp.
Compared to previous flat panel sensors, the C9321SK-05 also offers higher frame rates of 9 frames per second at full resolution and the device is capable of realtime imaging at 27 frames per second with 2 x 2 binning.[1]