Gr-smart meters Setup Guide: Difference between revisions

No edit summary
Line 201: Line 201:
Follow instructions to make
Follow instructions to make
===Provide reveng four good packets===
===Provide reveng four good packets===
I find the easiest way to do this is to limit the '''Packet Type''' to 0x55 and '''Packet Length''' to 0x23. Edit the GridStream block and make those changes then run the flowgraph making sure '''CRC Enable''' is set to False. You will get data that looks like this below.
I find the easiest way to do this is to limit the '''Packet Type''' to 0x55 and '''Packet Length''' to 0x23. Edit the GridStream block and make those changes then run the flowgraph making sure '''CRC Enable''' is set to False.  
<code> 00FF2A55002330FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286 </code>
 
You will get data that looks like this below.
 
<code>00FF2A55002330FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286</code>
 
You need to remove the first 6 bytes and provide the rest as inputs to reveng, CRC isn't calculated on those bytes.
You need to remove the first 6 bytes and provide the rest as inputs to reveng, CRC isn't calculated on those bytes.
<code> 00FF2A550023 <-- Discard | 30FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286 </code>
 
<code>00FF2A550023 <-- Discard | 30FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286</code>
 
Now provide four samples to reveng
Now provide four samples to reveng
<code> ./reveng -w 16 -s 30FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286 30FFFFFFFFFFFF50CF2DD9E560560065F5D5A483F0C000650100176C033FF77E901766 30FFFFFFFFFFFF50CF95D9E5E01A0065F5D9A483F0515A0201001E6C042A177E90BDA4 30FFFFFFFFFFFF50CF8DD9E6A0F00065F5EBA483F0EBFD4A0100206C0433A97E90B04C </code>
 
<code>./reveng -w 16 -s 30FFFFFFFFFFFF50CF5DD9E2C0B80065F5D1A483F0FBBC6F01001E6C043B517E90B286 30FFFFFFFFFFFF50CF2DD9E560560065F5D5A483F0C000650100176C033FF77E901766 30FFFFFFFFFFFF50CF95D9E5E01A0065F5D9A483F0515A0201001E6C042A177E90BDA4 30FFFFFFFFFFFF50CF8DD9E6A0F00065F5EBA483F0EBFD4A0100206C0433A97E90B04C</code>
 
You should get the following output below if you used this data to test
You should get the following output below if you used this data to test
<code>width=16  poly=0x1021  init=0x5fd6  refin=false  refout=false  xorout=0x0000  check=0x139e  residue=0x0000  name=(none)</code>
<code>width=16  poly=0x1021  init=0x5fd6  refin=false  refout=false  xorout=0x0000  check=0x139e  residue=0x0000  name=(none)</code>
The init value is what you enter into the GridStream block, you can now enable the CRC and know you have correct data!
The init value is what you enter into the GridStream block, you can now enable the CRC and know you have correct data!