MT174: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
mNo edit summary |
||
| Line 10: | Line 10: | ||
The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models. | The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models. | ||
The "Fatal counter" is a hex value 8bit flag register: | The "Fatal counter" is a hex value 8bit flag register: | ||
0 = Firmware error | 0 = Firmware error | ||
1 = Counter parameter checksum error | 1 = Counter parameter checksum error | ||
2 = energy/maximum checksum error | 2 = energy/maximum checksum error | ||
3 = not used | 3 = not used | ||
4 = not used | 4 = not used | ||
5 = not used | 5 = not used | ||
6 = maintenance warning level (?) | 6 = maintenance warning level (?) | ||
7 = not used | 7 = not used | ||
[https://www.youtube.com/watch?v=fOnKzUN7SzU Tampering / manipulation log video] | |||
[https://www.youtube.com/watch?v=fOnKzUN7SzU Tampering / manipulation log video] | |||
[[File:ISKRA LOG.png|thumb|FIFO logbook P.98.1 for 74 "possible misuse type events"]] | [[File:ISKRA LOG.png|thumb|FIFO logbook P.98.1 for 74 "possible misuse type events"]] | ||
Revision as of 21:16, 8 March 2024
ISKRA MT174

ISKRA MT174 (230/400V, rated 85A) mostly used in Saxonia this seems to have some noticable semaphores wich can be visualy inspected:
KD = lid/cover open (there must be a switch somewhere) BAT = internal battery low DÜ = transmission mode FF = "Fatal" counter (?) SET = counter in program mode
The IR-Interface is claimed to be IEC 62056-21 mode C (asynchron, half-duplex, 300 - 19.200 baud, 7bit, even parity, 1stop (1_7D_1P_E_1S) and it is bidirectional. So one can also send something over that interface. There's an optional RS485 wire interface on some models.
The "Fatal counter" is a hex value 8bit flag register:
0 = Firmware error 1 = Counter parameter checksum error 2 = energy/maximum checksum error 3 = not used 4 = not used 5 = not used 6 = maintenance warning level (?) 7 = not used
Tampering / manipulation log video