Mermaid:Mechanic L1 Pro Failure Sequence
sequenceDiagram
participant User
participant PowerButton
participant QX9920
participant Q1
participant LED
User->>PowerButton: Turns lamp ON directly
Note over PowerButton,QX9920: Timer bypassed - no auto cutoff scheduled
PowerButton->>QX9920: VIN applied, EN held high continuously
QX9920->>Q1: DRV switches gate at full duty, cycle after cycle
Q1->>LED: Sustained drive current, no rest period
loop Extended runtime with no shutoff
Q1->>Q1: Conduction + switching losses generate heat
Note over Q1: Heat dissipation can't keep pace with duration
end
Note over Q1: Junction temperature exceeds rated max
Q1-->>Q1: Thermal failure (commonly fails shorted D-S)
Q1->>LED: Uncontrolled current - CS feedback loop no longer limits it
Note over LED: LED experiences overcurrent stress from failed Q1
sequenceDiagram
participant User
participant PowerButton
participant QX9920
participant Q1
participant LED
User->>PowerButton: Turns lamp ON directly
Note over PowerButton,QX9920: Timer bypassed - no auto cutoff scheduled
PowerButton->>QX9920: VIN applied, EN held high continuously
QX9920->>Q1: DRV switches gate at full duty, cycle after cycle
Q1->>LED: Sustained drive current, no rest period
loop Extended runtime with no shutoff
Q1->>Q1: Conduction + switching losses generate heat
Note over Q1: Heat dissipation can't keep pace with duration
end
Note over Q1: Junction temperature exceeds rated max
Q1-->>Q1: Thermal failure (commonly fails shorted D-S)
Q1->>LED: Uncontrolled current - CS feedback loop no longer limits it
Note over LED: LED experiences overcurrent stress from failed Q1