Difference between revisions of "Landis+Gyr GridStream Protocol"
		
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
		
		
		
		
		
	
| Line 4: | Line 4: | ||
File:LandisGyrResidentialMeter1.JPG  | File:LandisGyrResidentialMeter1.JPG  | ||
</gallery>  | </gallery>  | ||
| + | |||
| + | === Sample Meter Data ===  | ||
| + | <code>1)      2)  3)   4) 5)       6)       7)   8)   9)     10)      11)  12)</code>  | ||
| + | |||
| + | <code>00FF2A  D5  0016 21 F05FCB84 F0FC4DB1 E288 0100 273205 00781930 CB72 00</code>  | ||
| + | |||
| + | <code>1) Header = 0x00FF2A</code>  | ||
| + | |||
| + | <code>2) Packet Type = 0xD5</code>  | ||
| + | |||
| + | <code>3) Packet Length = 0x0016</code>  | ||
| + | |||
| + | <code>4) Unknown Identifier #1 = 0x21</code>  | ||
| + | |||
| + | <code>5) Meter #1 ID = F05FCB84</code>  | ||
| + | |||
| + | <code>6) Meter #2 ID = F0FC4DB1</code>  | ||
| + | |||
| + | <code>7) Unknown Identifier #2 = 0xE288</code>  | ||
| + | |||
| + | <code>8) Unknown Identifier #3 = 0x0100</code>  | ||
| + | |||
| + | <code>9) Unknown Data #1 = 0x273205</code>  | ||
| + | |||
| + | <code>10) Unknown Data #2 = 0x00781930</code>  | ||
| + | |||
| + | <code>11) Checksum = 0xCB72</code>  | ||
| + | |||
| + | <code>12) Trailing byte = 0x00</code>  | ||
| + | <br />  | ||
Revision as of 00:28, 22 February 2021
Sample Meter Data
1)      2)  3)   4) 5)       6)       7)   8)   9)     10)      11)  12)
00FF2A  D5  0016 21 F05FCB84 F0FC4DB1 E288 0100 273205 00781930 CB72 00
1) Header = 0x00FF2A
2) Packet Type = 0xD5
3) Packet Length = 0x0016
4) Unknown Identifier #1 = 0x21
5) Meter #1 ID = F05FCB84
6) Meter #2 ID = F0FC4DB1
7) Unknown Identifier #2 = 0xE288
8) Unknown Identifier #3 = 0x0100
9) Unknown Data #1 = 0x273205
10) Unknown Data #2 = 0x00781930
11) Checksum = 0xCB72
12) Trailing byte = 0x00